BATHROOM HEATER WITH ELECTRONIC THERMOSTAT 1200W GRAPHITE (GL01.1200GT)
BATHROOM HEATER WITH ELECTRONIC THERMOSTAT 1200W GRAPHITE (GL01.1200GT)
BATHROOM HEATER WITH ELECTRONIC THERMOSTAT 1200W GRAPHITE (GL01.1200GT)
BATHROOM HEATER WITH ELECTRONIC THERMOSTAT 1200W GRAPHITE (GL01.1200GT)
BATHROOM HEATER WITH ELECTRONIC THERMOSTAT 1200W GRAPHITE (GL01.1200GT)
BATHROOM HEATER WITH ELECTRONIC THERMOSTAT 1200W GRAPHITE (GL01.1200GT)
BATHROOM HEATER WITH ELECTRONIC THERMOSTAT 1200W GRAPHITE (GL01.1200GT)
BATHROOM HEATER WITH ELECTRONIC THERMOSTAT 1200W GRAPHITE (GL01.1200GT)
BATHROOM HEATER WITH ELECTRONIC THERMOSTAT 1200W GRAPHITE (GL01.1200GT)
BATHROOM HEATER WITH ELECTRONIC THERMOSTAT 1200W GRAPHITE (GL01.1200GT)
BATHROOM HEATER WITH ELECTRONIC THERMOSTAT 1200W GRAPHITE (GL01.1200GT)
BATHROOM HEATER WITH ELECTRONIC THERMOSTAT 1200W GRAPHITE (GL01.1200GT)

BATHROOM HEATER WITH ELECTRONIC THERMOSTAT 1200W GRAPHITE (GL01.1200GT)

41,87 EUR
incl. VAT /
Lowest price in 30 days before discount: /
Regular price: /
of
14 days for easy returns
Find out in which store you can check the product and buy it right away
BATHROOM HEATER WITH ELECTRONIC THERMOSTAT 1200W GRAPHITE (GL01.1200GT)
BATHROOM HEATER WITH ELECTRONIC THERMOSTAT 1200W GRAPHITE (GL01.1200GT)
Safe shopping

Intended use

The electric heating element with a temperature control is intended to heat water in a bathroom radiator (stand-alone water radiator or connected to a central heating system). The device is intended for domestic use.

Technical characteristics

The device consists of a 1200W heating element, an electronic thermostat that provides temperature control of the water in the heater, and a power cord with a universal plug. The illumination of an indicator light indicates the operation of the heater.

High quality device, confirmed by CE certificate.

The heater must be installed by a qualified installer in accordance with the applicable regulations and standards of the local area and the manufacturer's recommendations. Any improper use is prohibited.

Exploitation contrary to the instructions (for purposes other than those intended by the manufacturer) and the performance of repairs by persons not authorized to do so may result in failure and void the warranty.

Placement and installation

  • The heater should be installed in a water radiator (stand-alone or connected to the central heating system), the design (structure and dimensions) of which allows its installation and has a suitable place for the installation of the heater;
  • The heater should be installed in rooms where the temperature is not lower than 5ºC and higher than 40ºC;
  • Safety requirements determine the permissible location and distance from wet places, including from the sink, shower, bathtub (the electric heater can be installed only in the III protection zone, that is, at a distance of at least 60 cm from wet zones). It is unacceptable to install heaters in radiators that are installed over the bathtub or in the shower room;

Detailed information on installation and use can be found in the user manual.


The heater must not be installed in tanks made of stainless steel.

Installation requirements

  • The heating and electrical installation should be made in accordance with applicable regulations, have an effective protective circuit, an overcurrent and residual current circuit breaker (30mA);
  • The design of the heater should allow collision-free installation of the heating element in the heater;
  • The heating element must not touch the internal parts of the heater;
  • Diameter of the connection spigot, should be in accordance with the dimensions of the thread of the heating element (reduction is allowed);
  • Depth (length) of the connection stub (socket), must be shorter than the length of the dead zone of the heating element (25mm);
  • Install in the lower part of the radiator in a vertical position (with the heating element upwards) only in the place intended for this purpose by the manufacturer of the radiator preserving space for proper circulation of the heating factor;

Detailed information on installation and use can be found in the user manual.


Installation and use

  • The heater is an electric heating device and is only a subassembly of the radiator;
  • The power of the heater installed in the radiator must not be greater than the heating power of the radiator, specified at parameters (75/65/20)°C. The heater's heating power is specified by the radiator manufacturer for the parameters of water temperature t =75 °C (supply), t =65 °C (return) and air temperature t =20 C;
  • The radiator connected to the central heating system with the heater installed must not be completely cut off from the central heating system, (both valves must not be closed at the same time - the water, which will expand under the influence of increased temperature, must be able to increase its volume);
  • In the radiator not connected to the central heating system, leave 5-8% free space (water, which will expand under the influence of increased temperature, must be able to increase in volume); - The heater should be sealed with the supplied rubber washer (recommended) or other available means to seal the installation site;
  • The position of the casing, should provide easy access to the knob (in case of unfavorable position of the heater, you can additionally seal, for example, with Teflon tape);
  • After installation of the heater, the radiator should be filled with water, vent the installation, and then check the tightness of the hydraulic connection in the place of installation of the heater;
  • Connect to electricity only after the radiator is filled with water, the heating element is completely immersed in water and vented;
  • Do not switch on without water (can cause permanent damage to the heating element) - Set the required water temperature with the dial;
  • It is forbidden to connect the module to the power supply if the heater is empty or the heating element is not completely immersed in water;

Detailed information on installation and use can be found in the user manual.


When choosing a heater, remember about the proper selection of the heater for the bathroom radiator.

See also:

Brand
Symbol
GL01.1200GT
Producer code
5901549235401
Series
TECHNICAL DATA
VOLTAGE
230V / 50 Hz
HEATER POWER
1200W
CURRENT
5,2 A
PROTECTION DEGREE
IP24
TEMPERATURE RANGE
13°C - 65°C +/- 2°C
CABLE LENGTH
1,5 m/ 3 x 0,75
THREAD
1/2"
WEIGHT
430 (g)
LENGTH (± 10mm)
485 (mm)
LENGTH OF THE HEATING ELEMENT L (± 10mm)
365 (mm)
EXTENSION
20 (mm)
TYPE
RD 10
PROTECTION CLASS
KL. I
WORK ENVIRONMENT
WATER
MATERIAL CHARACTERISTICS
CASE
ABS
FILL MATERIAL
STEEL
HEATING ELEMENT COVER TUBE
COPPER
Do you need help? Do you have any questions?Ask a question and we'll respond promptly, publishing the most interesting questions and answers for others.
Ask a question
If this description is not sufficient, please send us a question to this product. We will reply as soon as possible. Data is processed in accordance with the privacy policy. By submitting data, you accept privacy policy provisions.
Sprzedawcy na okres 24 miesięcy.
Sprzedawcy na okres 24 miesięcy.
Write your opinion
Your opinion:
5/5
Add your own product photo:
This page uses cookie files to provide its services in accordance to Cookies Usage Policy. You can determine conditions of storing or access to cookie files in your web browser.
Close
pixelpixel